AS-Schneider Soft Seated Direct Mount 5 Valve Manifolds H5S/H5L Type are flanged on the process side to an Orifice Meter-Stabilized connector-(if necessary Spacer / 2 Valve Manifold)-Assembly and on the outlet to a Differential Pressure Transmitter resp. an Adapter-Transmitter-Assembly. The standard vent connection is 1/4 NPT female and is supplied with a fitted Bug Plug. The test ports 1/4 NPT female are plugged by default. Accessory Kits incl. washers are required for manifold to transmitter mounting, because the manifolds are provided with slotted bolt holes. The H5S Type is used for Vertical Installations. The H5L Type is applicable for Horizontal Installations. Bore Size: – Isolate Valves – 3/8″ (9.5 mm) – Equalize and Vent Valves – 0.138″ (3.5 mm) The process to instrument connection is fully roddable due to the Cone Design Valve Seat of the Isolate Valves.
A diverse range of options and the relevant accessories are available; please see below Mounting Bracket Kits and Accessories.
Technical specification of instrumentation valves
Manifold 5 valves of Schneider company model W5AASA-N4TD-2A |
Model and manufacturer |
Manifold 5 valves |
Valve type |
gear |
Connection type |
(NPT-F)"1/2 |
Output connection (Process) |
(NPT-F)"1/2 |
Input connection (Instrument) |
316L steel |
body material |
6000psi |
Push class |
232 ℃ |
working temperature |