Specs at a glance
-
Accuracy
Standard 0.15% Platinum 0.075% -
Process temperature
-70°C…400°C (-94°F…752°F) -
Pressure measuring range
1 bar…400 bar (15 psi…6000 psi) -
Process pressure / max. overpressure limit
600 bar (9000 psi) -
Main wetted parts
316L AlloyC Montel Tantal Rhodium -
Max. measurement distance
4000m (13.123ft) H2O -
Material process membrane
316L, AlloyC, Tantal, PTFE, Rhodium>Gold -
Measuring cell
400 mbar…400 bar (5.8 psi…6000 psi) relative/ absolute
Field of application
The Cerabar PMP55 digital pressure transmitter with metal diaphragm seal is typically used in process and hygiene applications for pressure, level, volume or mass measurement in liquids. Suitable for high pressure as well as extreme process temperature applications from -70 up to +400°C (-94 to 750°F). Quick Setup with adjustable measuring range allows simple commissioning, reduces costs and saves time. SIL2 according to IEC 61508 and IEC 61511.
Single chamber aluminum or stainless steel (316L) housing.
-
Process connections: Threads, flanges or hygienic connections
-
Process temperature: -70 to +400°C (-94 to +752°F)
-
Measuring ranges: -1/0 up to +400bar (-15/0 up to +6,000psi)
-
Accuracy: ±0.15%, “Platinum” ±0.075%
-
International explosion protection certificates, SIL, hygienic approvals, marine approvals
Benefits
-
Large variety of different process connections and membrane materials
-
New TempC Membrane minimizes influences of ambient and process temperature fluctuations
-
Easy menu-guided commissioning via on-site display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
-
For process pressure monitoring up to SIL2, certified to IEC 61508 and IEC 61511
-
Modular concept for easy replacement of display or electronics
-
Seamless and independent system integration (HART/PA/FF)
Technical specifications of high pressure transmitters
Endress Hauser diaphragm pressure transmitter PMP55-AA21JA1HGJCXJA1A+PA |
Model and manufacturer |
|
diaphragm pressure transmitter |
Type of pressure transmitter |
|
bar |
Pressure measurement unit |
|
1⁓1- |
Measurable range |
|
1- |
Minimum measurement range |
|
1 |
Maximum measurement range |
|
|
Output/communication protocol |
|
Aluminum |
Body material |
|
SS 316L |
Connection material |
|
Hastelloy C276 |
Sensor material (diaphragm) |
|
flange |
Connection type |
|
"2 |
Connection size |
|
Digital |
Display |
|
-400⁓70℃ |
Process temperature |
|
IP66 |
IP degree of protection |
|
No |
Anti-explosion degree of protection (Ex) |
|
|